Manufactured in the testing and calibration of the 0.1 Class(and below) single phase meter and three phase meter, the DF6373 three phase smart meter on-site calibrator has the functions of meter accuracy test, electrical parameter test, transformation ratio test, harmonic test, correction of the wrong connection, data storage and reading, etc.
●With the application of the digital reactive measurement technology, the test process of the equipment won’t be affected by the unbalance of the voltage¤t, the unsymmetry of phase angle and the frequency changing;
●The equipment can test active(reactive) power, voltage, current, frequency and phase , it also has the all parameter software modification function;
●High brightness, high definition, high resolution(No less than 640*480),large color LCD display;
●Wide working voltage range: AC 30~480V.The equipment can ensure the accuracy of the energy metering;
●The equipment can test the positive sequence, negative sequence, zero sequence and the imbalance of the voltage and current;
●Voltage auto-switch:0-480V, Current input(direct):5A;
●Equipped with the 0.2 Class 5A Clamp Meter, the equipment can test the switching none repeating error, contact error, angle error. etc.
●With the light and beautiful design of the appearance, the equipment is convenience for using in the field.
Test voltage, current range |
Voltage limit:0-480V |
Accuracy:0.05%Un |
Current limit:0-24A |
Accuracy:0.05%In |
|
Clamp connected:1A、5A、10A、20A、50A、100A。 |
Accuracy:0.2% |
|
PT secondary load |
Admittance(ms): 99.99
|
Less than ±2%, reading ±0.02ms |
Less than ±2%, reading ±0.02VA |
||
CT secondary load |
Impedance(Ω):10.00 |
Accuracy: Less than ±2%, reading ±0.01Ω |
Operation Load(VA):75 |
Accuracy: Less than ±2%, reading ±0.2VA |
|
Phase frequency measurement |
Testing Phase:0-360 |
Accuracy:±0.05° |
Testing Frequency:45-65Hz |
Accuracy:±0.01Hz |
|
Secondary side loop voltage drop
|
Ratio difference: 0 ~ ±10% |
Accuracy:±0.02% |
Phase angle: 0 ~ ±600′ |
Accuracy:±0.5′ |
|
Frequency:47.5Hz~ 52.5Hz |
Accuracy:±0.1Hz。 |
|
Voltage:57.7V(1±20%) |
100V(1±20%)。 |