DF6373 Three Phase Smart Meter On-site Calibrator
Overview:

Manufactured in the testing and calibration of the 0.1 Class(and below) single phase meter and three phase meter, the DF6373 three phase smart meter on-site calibrator has the functions of meter accuracy test, electrical parameter test, transformation ratio test, harmonic test, correction of the wrong connection, data storage and reading, etc.


Product feature:

●With the application of the digital reactive measurement technology, the test process of the equipment won’t be affected by the unbalance of the voltage¤t, the unsymmetry of phase angle and the frequency changing;

●The equipment can test active(reactive) power, voltage, current, frequency and phase , it also has the all parameter software modification function;

●High brightness, high definition, high resolution(No less than 640*480),large color LCD display;

●Wide working voltage range: AC 30~480V.The equipment can ensure the accuracy of the energy metering;

●The equipment can test the positive sequence, negative sequence, zero sequence and the imbalance of the voltage and current;

●Voltage auto-switch:0-480V, Current input(direct):5A;

●Equipped with the 0.2 Class 5A Clamp Meter, the equipment can test the switching none repeating error, contact error, angle error. etc.

●With the light and beautiful design of the appearance, the equipment is convenience for using in the field.


Technical Parameters:

 

Test voltage, current range

Voltage limit:0-480V

Accuracy:0.05%Un

Current limit:0-24A

Accuracy:0.05%In

Clamp connected:1A、5A、10A、20A、50A、100A。

Accuracy:0.2%

PT secondary load

Admittance(ms): 99.99

 

Accuracy:

Less than ±2%, reading ±0.02ms

Operation Load(VA):500

Accuracy:

Less than ±2%, reading ±0.02VA

CT secondary load

Impedance(Ω):10.00

Accuracy:

Less than ±2%, reading ±0.01Ω

Operation Load(VA):75

Accuracy:

Less than ±2%, reading ±0.2VA

Phase frequency measurement

Testing Phase:0-360

Accuracy:±0.05°

Testing Frequency:45-65Hz

Accuracy:±0.01Hz

Secondary side loop voltage drop

 

Ratio difference: 0 ~ ±10%

Accuracy:±0.02%

Phase angle: 0 ~ ±600′

Accuracy:±0.5′

Frequency:47.5Hz~ 52.5Hz

Accuracy:±0.1Hz。

Voltage:57.7V(1±20%)

100V(1±20%)。