Your Position:Home > Products&Solutions > DF6373 Three Phase Smart Meter On-site Calibrator

Products&Solutions

Testing & Calibration Equipment
DF6373 Three Phase Smart Meter On-site Calibrator

Manufactured in the testing and calibration of the 0.1 Class(and below) single phase meter and three phase meter, the DF6373 three phase smart meter on-site calibrator has the functions of meter accuracy test, electrical parameter test, transformation ratio test, harmonic test, correction of the wrong connection, data storage and reading, etc.

  • With the application of the digital reactive measurement technology, the test process of the equipment won’t be affected by the unbalance of the voltage¤t, the unsymmetry of phase angle and the frequency changing;

    The equipment can test active(reactive) power, voltage, current, frequency and phase , it also has the all parameter software modification function;

    High brightness, high definition, high resolution(No less than 640*480),large color LCD display;

    Wide working voltage range: AC 30~480V.The equipment can ensure the accuracy of the energy metering;

    The equipment can test the positive sequence, negative sequence, zero sequence and the imbalance of the voltage and current;

    Voltage auto-switch:0-480V, Current input(direct):5A;

    Equipped with the 0.2 Class 5A Clamp Meter, the equipment can test the switching none repeating error, contact error, angle error. etc.

    With the light and beautiful design of the appearance, the equipment is convenience for using in the field.

  •  

    Test voltage, current range

    Voltage limit0-480V

    Accuracy:0.05%Un

    Current limit:0-24A

    Accuracy:0.05%In

    Clamp connected1A、5A、10A、20A、50A、100A。

    Accuracy:0.2%

    PT secondary load

    Admittance(ms): 99.99

     

    Accuracy

    Less than ±2%, reading ±0.02ms

    Operation Load(VA):500

    Accuracy

    Less than ±2%, reading ±0.02VA

    CT secondary load

    Impedance(Ω):10.00

    Accuracy

    Less than ±2%, reading ±0.01Ω

    Operation Load(VA):75

    Accuracy

    Less than ±2%, reading ±0.2VA

    Phase frequency measurement

    Testing Phase:0-360

    Accuracy:±0.05°

    Testing Frequency:45-65Hz

    Accuracy:±0.01Hz

    Secondary side loop voltage drop

     

    Ratio difference: 0 ~ ±10%

    Accuracy:±0.02%

    Phase angle: 0 ~ ±600′

    Accuracy:±0.5′

    Frequency:47.5Hz~ 52.5Hz

    Accuracy:±0.1Hz。

    Voltage:57.7V(1±20%)

    100V(1±20%)。


Contact

Email: imeter@dongfang-china.com                  Tel: (86)0535-2916790    Fax: (86)0535-2916291
Website: Https://en.dongfang-wisdom.com         Skype : bingather