Your Position:Home > Products&Solutions > DF6501 Power Quality Monitoring Equipment

Products&Solutions

Power Quality Monitoring Equipment
DF6501 Power Quality Monitoring Equipment

DF6501-PQA power quality monitoring equipment can quickly detect the transient events (up to 24µs) such as voltage swell, sag, and interruption. The flexible configuration enables the product to meet various needs of users, and helps to fully monitor the power quality problems.

  • High-speed sampling, fast capture voltage disturbance events

    A variety of recording trigger mode, power function of black box

    Powerful functions of statistical features

    Rich functions of communication features

    Advanced functions of hardware architecture

  • Multifunctional Data Displaying Feature

    Equipped with large-size color LCD, easy access to all monitoring indicators data, events, recorded wave waveform,also data files easy to be exported with standard USB interface.

    Remote Input,output.

    Function of GPS time synchronization

    Monitor Function(refer to Table 1)

    Index Parameter

    Content

    Basic Electric Parameter

    Voltage of three-phases,Current of three-phases,Active power,Reactive power,Power factor,Frequency

    Fundamental Wave

    Voltage/Current Effective Value

    Voltage/Current Phase

    Active power,Reactive power,Apparent power,Power factor,

    Phase shifting power factor

    Harmonic Wave

    Voltage/Current Total HD

    Voltage/Current Total Odd HD

    Voltage/Current Total Even HD

    Effective Value of Harmonic Voltage/Current(Harmonic Ratio)

    Harmonic Voltage/Current Phase

    62.5 Inter-harmonics

    Harmonic Power

    Inter-harmonics

    Inter-harmonic Voltage/Current

    Imbalance

    Voltage/Current Component and Unbalance

    Voltage Flicker

    Short Time Voltage Flicker

    Long Time Voltage Flicker

    Voltage Fluctuation

    Voltage Fluctuation

    Temporary lift/temporary drop

    Event Record

    Short Interruption

     

    Event Record

    Transient Events

     Event Record

  •  

    Item

    Technical Standard

    Operation Voltage

    AC220V±20%50HzDC:220V/110V

    AC:220V±20%50Hz,DC:220V/110V

    Current Range

    1A/5A 

    Voltage Range

    100V  

    Frequency Range

    Test Range47.5Hz52.5Hz

    Power Consumption

    15W,25VA


Contact

Email: imeter@dongfang-china.com                  Tel: (86)0535-2916790    Fax: (86)0535-2916291
Website: Https://en.dongfang-wisdom.com         Skype : bingather